Practical guidance
A wardrobe-lighting quote should describe a working, serviceable installation. The strip price is only one line. Compare suppliers using the same illuminated bays, controls, profiles, electrical components and joinery preparation so their totals refer to the same result.
## Count the actual lighting runs
Mark each vertical and horizontal run on the wardrobe drawing and calculate its installed length. Distinguish the length of illuminated strip from cable length and from the number of separately controlled zones.
Specify the intended light appearance and compare a working sample. A quote for bare strip is different from one including an aluminium profile and diffuser. If a 7 m wardrobe contains several short runs, the lighting quantity is not automatically 7 m. Read the elevation bay by bay.

Itemise components and trade work
List strips, profiles, covers, end pieces, compatible drivers, controls, sensors, connectors and required wiring. Ask who selects the electrical components and who completes connections. The cabinet maker's routing and removable access panels should also be accounted for.
Include testing, commissioning and any work needed to bring a suitable supply to the wardrobe. A price that excludes electrical preparation may appear attractive while leaving a substantial part of the installation unassigned. Identify those boundaries before the interior panels are closed.
Price maintenance as part of the decision
Ask how strips and drivers are replaced, which parts are readily obtainable and whether all components are identified in the handover record. If a driver is hidden in an inaccessible compartment, the future labour can outweigh a small initial saving.
Compare the finished lighting quality and agreed scope before accepting a variation. Where a component changes, approve its compatibility and appearance. Keep a dated quotation with the final lengths, quantities and tax treatment clearly shown. Obtain local prices for the actual installation rather than extrapolating from a foreign-market discussion.
## A practical check before you decide
Create a lighting schedule with one row for each run and columns for length, profile, control zone and driver connection. Have the carpenter and electrician mark what each supplies. Compare revised totals after every missing preparation or component has been included.
## Use a bay schedule instead of a strip-only comparison
Label each illuminated compartment on the wardrobe drawing. For every bay, identify the intended light run, control and accessible power component. Ask each supplier to price that same arrangement. A quotation based on a single long strip cannot be compared directly with several independently controlled compartments.
Separate the light source, profile, diffuser, end pieces, wiring, connectors, controls, power components and installation. Add the cabinet preparation and any removable panels. Ask who supplies each item and who checks compatibility. Keep provisional allowances clearly labelled so a missing component does not become a surprise after fabrication.
## Include the work needed for a later repair
Ask the installer to show where the driver and connections can be reached after the wardrobe is filled. A concealed component still needs a practical removal route. Include the responsibility for opening and reinstating decorative covers during maintenance, and ask which replacement references will be provided at handover.
Approve a working sample with the actual strip, profile, cover and control before accepting a substitution. Record whether the quoted scope includes testing, cleanup and demonstration of every bay. At completion, operate the system with representative clothing in place and compare it with the approved sample. Keep the final component schedule and cabinet drawings together. This makes the quote a description of a serviceable installation, rather than a low headline price for only one visible component.
## Match the profile as a complete component
Hafele Home lists Loox profile 2193 with a 16 mm diffuser and 16.6 mm internal width in its product notes. These are component dimensions, not a routing template. The listed profile also leaves LED points visible. Ask for the actual locally supplied strip-and-profile assembly to be demonstrated, and specify the approved combination rather than assuming every covered strip creates the same appearance.

Questions people ask us
Does price per metre include the driver?
Only if the quotation states that inclusion explicitly.
Why do short runs increase complexity?
They may require more connections, profiles, controls or preparation than one uninterrupted run.
Who should prepare lighting recesses?
Coordinate the cabinet maker with the lighting specification before fabrication.
Should maintenance access be priced?
Yes. Include any removable panels or preparation needed for servicing.
Does this guide supply a current rate?
No. Request dated local quotes for the same defined installation.