Practical guidance
Neat under-cabinet lighting needs a planned route for the profile, cables and driver. Decide where each component goes before the finished cabinet bottoms and backsplash are closed. The installation should look tidy from a dining chair as well as from the worktop.
## Draw a continuous route across the run
Mark where light starts and stops, how it turns corners and how it passes between adjoining cupboards. Separate the desired light line from the cable route. They do not always follow the same path.
Ask the joinery maker to show any prepared holes or recesses on the fabrication drawing. A notch proposed after installation should be assessed against the cabinet construction rather than cut casually through a finished part. Include the cooker hood, tall unit and exposed end in the route.

Hide components without trapping them
The profile may be surface-mounted behind a trim or recessed into a prepared panel. Compare these choices from the room's normal seated positions. Check whether the cabinet underside needs a finished skin and whether that skin remains removable where service access is necessary.
Have an electrician specify compatible electrical components and connections. Identify where the driver and any controller can be reached after installation. A tiny service opening is useful only if the component can actually pass through it and the person servicing it can work safely.
Coordinate cleaning and replacement
Choose a location that can be wiped without exposing unprotected components to water or cooking residue. Product suitability near a sink or hob must be checked with its supplier and the appliance requirements. A decorative cover does not by itself establish suitability.
At completion, test the whole run, switches and dimming. Check joints for dark interruptions or conspicuous wires. Keep photographs of the concealed route before closure and retain all component references. This makes a future strip replacement much easier than guessing how the original installation was assembled.
## A practical check before you decide
Ask for a cabinet underside drawing showing profile position, cable entry, cabinet crossings, driver location and service panel. View the first installed section from the dining seat. Approve the concealment and light quality there before the remaining run is completed.
## Specify the recess before the panel is made
Treat the cabinet underside as a construction detail. A profile mounted to a removable cover is different from a groove cut directly into a load-bearing panel. Ask the cabinet maker to draw the remaining material beneath and beside any recess, the fixing positions and the connection to adjoining cabinets. If the required groove cannot be accommodated, revise the design rather than allowing an installer to deepen it on site.
For a concrete component example, Hafele Home lists Loox profile 2193 with a 16 mm diffuser and 16.6 mm internal width. Those are product dimensions, not the size of a recess to cut. Its notes also warn that LED points remain visible, so concealment and a continuous-looking light line are separate approvals. Consult the product notes and the instructions for the exact locally supplied component.
## Walk through a future repair
Ask the installer to demonstrate how the cover comes off, how a failed strip is reached and how the driver is removed with the cabinets full. A connection that can be seen through an opening may still be impossible to disconnect or replace there. Label which switch controls the installation and retain the electrical component schedule with the cabinet drawing. Let the electrician handle isolation and connections.
Before accepting the first completed run, inspect the exposed end, corner and cabinet junction. Check that cleaning does not require pulling on wires or removing a fragile decorative edge. Photograph the route while it is open and keep the approved underside detail. If you later change the backsplash thickness or add a front trim, repeat the sight-line check: both can alter the way the lighting is seen from the room.

Questions people ask us
Is recessed lighting always better looking?
It can be discreet, but preparation, depth and serviceability must suit the cabinet.
Can wiring simply run behind the backsplash?
The electrician and installer need an approved route and accessible connections.
Should drivers be hidden permanently?
Provide the access required for safe servicing and replacement.
How do I avoid visible wires at cabinet joints?
Plan cable crossings before fabrication and inspect a representative junction.
What photographs should I keep?
Record concealed routes, component locations and access points before they are covered.